Fire/Smoke Damper

medium 7 / 7 Modelle (Inspector)
Marine fire and smoke dampers for ventilation system fire safety
Inspector Mode Show All 7 / 7 with inspector value

4 Hersteller · 7 Modelle

🏭

Kongsberg

4 ✓ 4 verifiziert
⚙️
Kongsberg Bronswerk FD-200 ✓ verifiziert
application: marine ventilation / fire safety
damper_type: fire damper
size_mm: 200
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T14:21:18.789816+00:00
confidence: high
⚙️
Kongsberg Bronswerk FD-400 ✓ verifiziert
application: marine ventilation / fire safety
damper_type: fire damper
size_mm: 400
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T14:21:18.789816+00:00
confidence: high
⚙️
Kongsberg Bronswerk FD-600 ✓ verifiziert
application: marine ventilation / fire safety
damper_type: fire damper
size_mm: 600
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T14:21:18.789816+00:00
confidence: high
⚙️
Kongsberg Bronswerk FD-800 ✓ verifiziert
application: marine ventilation / fire safety
damper_type: fire damper
size_mm: 800
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T14:21:18.789816+00:00
confidence: high
🏭

Barclay

1 ✓ 1 verifiziert
⚙️
Marine Fire Damper A-60 ✓ verifiziert PREMIUM
Various duct sizes · Conditioned Air / Exhaust Air · Fire Damper A-60
type: Fire Damper A-60
Common Failures:
  • • Fusible link corrosion
  • • Blade binding from paint/corrosion
  • • Actuator failure
  • • Indication switch fault
Service: SOLAS A-60 fire integrity. Test closure monthly. Replace fusible links every 5 years. PSC inspection focus item.
Spares: Barclay: Lüftermotor-Lager und Keilriemen an Bord vorhalten. Lead time: 2-4 Wochen.
🏭

Ginge-Kerr

1 ✓ 1 verifiziert
⚙️
Marine Fire/Smoke Damper ✓ verifiziert PREMIUM
Various duct sizes · Conditioned Air / Exhaust Air · Fire/Smoke Damper A-60
type: Fire/Smoke Damper A-60
Common Failures:
  • • Blade corrosion
  • • Fusible link aging
  • • Motor actuator failure
  • • Microswich failure
Service: Ginge-Kerr established marine brand. Monthly operation test. Annual full inspection per class requirements.
Spares: Ginge-Kerr: Lüftermotor-Lager und Keilriemen an Bord vorhalten. Lead time: 2-4 Wochen.
🏭

Novenco Marine & Offshore

1 ✓ 1 verifiziert
Novenco Marine & Offshore Marine Fire/Smoke Damper
Marine Fire/Smoke Damper ✓ verifiziert PREMIUM
Various duct sizes · Conditioned Air / Exhaust Air · Fire/Smoke Damper A-60
type: Fire/Smoke Damper A-60
Common Failures:
  • • Actuator spring failure
  • • Blade seal degradation
  • • Position indicator fault
  • • Control circuit wire damage
Service: Dual-purpose fire/smoke damper. Monthly test per SOLAS. Annual full-stroke test with fire alarm integration.
Spares: Novenco Marine & Offshore: Lüftermotor-Lager und Keilriemen an Bord vorhalten. Lead time: 2-4 Wochen.