OS
← Ventilation

Fire/Smoke Damper

medium
Marine fire and smoke dampers for ventilation system fire safety

Known Models (3)

Barclay Marine Fire Damper A-60
Barclay Marine Fire Damper A-60
Various duct sizes · Conditioned Air / Exhaust Air · Fire Damper A-60
type: Fire Damper A-60
Common Failures:
  • • Fusible link corrosion
  • • Blade binding from paint/corrosion
  • • Actuator failure
  • • Indication switch fault
Service: SOLAS A-60 fire integrity. Test closure monthly. Replace fusible links every 5 years. PSC inspection focus item.
Spares: Barclay: Lüftermotor-Lager und Keilriemen an Bord vorhalten. Lead time: 2-4 Wochen.
Ginge-Kerr Marine Fire/Smoke Damper
Ginge-Kerr Marine Fire/Smoke Damper
Various duct sizes · Conditioned Air / Exhaust Air · Fire/Smoke Damper A-60
type: Fire/Smoke Damper A-60
Common Failures:
  • • Blade corrosion
  • • Fusible link aging
  • • Motor actuator failure
  • • Microswich failure
Service: Ginge-Kerr established marine brand. Monthly operation test. Annual full inspection per class requirements.
Spares: Ginge-Kerr: Lüftermotor-Lager und Keilriemen an Bord vorhalten. Lead time: 2-4 Wochen.
Novenco Marine & Offshore Marine Fire/Smoke Damper
Novenco Marine & Offshore Marine Fire/Smoke Damper
Various duct sizes · Conditioned Air / Exhaust Air · Fire/Smoke Damper A-60
type: Fire/Smoke Damper A-60
Common Failures:
  • • Actuator spring failure
  • • Blade seal degradation
  • • Position indicator fault
  • • Control circuit wire damage
Service: Dual-purpose fire/smoke damper. Monthly test per SOLAS. Annual full-stroke test with fire alarm integration.
Spares: Novenco Marine & Offshore: Lüftermotor-Lager und Keilriemen an Bord vorhalten. Lead time: 2-4 Wochen.