Wird verarbeitet…
OSM

Composite Boiler

high 2 / 49 Modelle (Inspector)
Combined oil-fired and exhaust gas boiler in one unit
4000h
Service Interval
25 yr
Typical Lifetime

Typical Manufacturers

Aalborg
Inspector Mode Show All 2 / 49 with inspector value

1 Hersteller · 2 Modelle

🏭

Aalborg

2 ✓ 2 verifiziert
⚙️
Mission OC Composite ✓ verifiziert Inspector
3000 kg/h steam · Steam (FO + Exhaust gas)
Common Failures:
  • • Soot fire in EGE section
  • • Burner lockout
  • • Water level gauge glass broken
  • • Safety valve lifting
Service: Combined unit; manage both firing modes; soot blow EGE section.
Spares: Aalborg: Brennerdüsen-Satz, Photoauge und Dichtungen an Bord vorhalten. Lead time: 3-8 Wochen für Rohre.
⚙️
XW-TG7 ✓ verifiziert Inspector
2000 kg/h steam · Steam (FO + Exhaust gas)
Common Failures:
  • • Tube leakage at tube plate
  • • Feed water control valve stuck
  • • Soot accumulation
Service: Older Aalborg composite design; water treatment and level control critical.
Spares: Aalborg: Brennerdüsen-Satz, Photoauge und Dichtungen an Bord vorhalten. Lead time: 3-8 Wochen für Rohre.