Wird verarbeitet…
OSM

Gas Detection (Fixed)

critical IMO Required 3 / 3 Modelle (Inspector)
Fixed multi-point gas detection system for engine room, pump room, cargo spaces.
4000h
Service Interval

Typical Manufacturers

Dräger Simtronics Honeywell MSA
Inspector Mode Show All 3 / 3 with inspector value

3 Hersteller · 3 Modelle

🏭

Dräger

1 ✓ 1 verifiziert
⚙️
Dräger Polytron 7000 Fixed Gas Detector ✓ verifiziert
Multi-gas, addressable, 4-20 mA + HART · Marine Equipment
Common Failures:
  • • Catalytic sensor poisoning
  • • Sampling pump diaphragm failure
  • • Junction box water ingress
Service: Calibration every 6 months with certified test gas. Sensor replacement every 2-3 years.
Spares: Dräger: Sicherheitsausrüstung per SOLAS-Mindestbestand. Lead time: 2-4 Wochen.
🏭

Honeywell

1 ✓ 1 verifiziert
⚙️
Honeywell Searchpoint Optima Plus ✓ verifiziert Inspector
0-100% LEL, IR open-path · Marine Equipment
Common Failures:
  • • Mirror alignment drift
  • • Bird/insect nesting in reflector
  • • Fog/condensation false alarms
Service: Alignment verification quarterly. Full calibration annually.
Spares: Honeywell: Sicherheitsausrüstung per SOLAS-Mindestbestand. Lead time: 2-4 Wochen.
🏭

Simtronics

1 ✓ 1 verifiziert
⚙️
Simtronics GD10P Fixed IR Gas Detector ✓ verifiziert Inspector
0-100% LEL, IR point detector · Marine Equipment · Infrared Gas Detection
Common Failures:
  • • Optical window contamination
  • • Heater element failure (cold climate)
  • • Signal cable water damage
Service: Window cleaning monthly. Full function test every 6 months.
Spares: Simtronics: Sicherheitsausrüstung per SOLAS-Mindestbestand. Lead time: 2-4 Wochen.
Pros
  • High accuracy in detecting gas leaks
  • Reliable operation in harsh environments
  • Low maintenance requirements with monthly window cleaning and bi-annual full function tests
Cons
  • Optical window contamination can lead to false readings
  • Heater element failure in cold climates can affect performance
  • Signal cable water damage can disrupt detection capabilities
Typical Vessels: TankerLNG CarrierOffshore Platform
Certifications: IEC 61508ATEX
Decision Guide: Choose if you require a reliable and accurate gas detection system for hazardous environments. Avoid if you are operating in extremely cold climates without proper heating measures or if optical window contamination is a significant concern.
Use Cases: Typically deployed in areas where gas leaks can occur, such as engine rooms, cargo tanks, and near processing equipment on vessels and offshore platforms.