Enclosed Space Entry Equipment
critical
IMO Required
2 / 14 Modelle (Inspector)
Equipment kit for safe enclosed space entry per SOLAS XI-1/7 and MSC.1/Circ.1401.
4000h
Service Interval
Typical Manufacturers
Dräger
MSA
2 Hersteller · 2 Modelle
🏭
Dräger
1 ✓ 1 verifiziert⚙️
Dräger Confined Space Entry Kit
✓ verifiziert
Inspector
Complete entry set with gas monitor, harness, rescue tripod
· Marine Equipment
Common Failures:
- • Gas monitor sensor expiry
- • Tripod locking pin wear
- • Rescue winch cable kinking
Service: Gas monitor calibration every 6 months. Tripod and winch load test annually. Harness inspection per EN 365.
Spares: Dräger: Sicherheitsausrüstung per SOLAS-Mindestbestand. Lead time: 2-4 Wochen.
🏭
MSA
1 ✓ 1 verifiziert⚙️
MSA Confined Space Entry Kit
✓ verifiziert
Entry set with Altair 5X, harness, tripod
· Marine Equipment
Common Failures:
- • Multi-gas sensor cross-sensitivity
- • Fall arrest indicator deployment
- • Winch handle mechanism jam
Service: Sensor replacement per MSA schedule. Annual load test of tripod and winch.
Spares: MSA: Sicherheitsausrüstung per SOLAS-Mindestbestand. Lead time: 2-4 Wochen.