Wird verarbeitet…
OSM

Enclosed Space Entry Equipment

critical IMO Required 2 / 14 Modelle (Inspector)
Equipment kit for safe enclosed space entry per SOLAS XI-1/7 and MSC.1/Circ.1401.
4000h
Service Interval

Typical Manufacturers

Dräger MSA
Inspector Mode Show All 2 / 14 with inspector value

2 Hersteller · 2 Modelle

🏭

Dräger

1 ✓ 1 verifiziert
⚙️
Dräger Confined Space Entry Kit ✓ verifiziert Inspector
Complete entry set with gas monitor, harness, rescue tripod · Marine Equipment
Common Failures:
  • • Gas monitor sensor expiry
  • • Tripod locking pin wear
  • • Rescue winch cable kinking
Service: Gas monitor calibration every 6 months. Tripod and winch load test annually. Harness inspection per EN 365.
Spares: Dräger: Sicherheitsausrüstung per SOLAS-Mindestbestand. Lead time: 2-4 Wochen.
🏭

MSA

1 ✓ 1 verifiziert
⚙️
MSA Confined Space Entry Kit ✓ verifiziert
Entry set with Altair 5X, harness, tripod · Marine Equipment
Common Failures:
  • • Multi-gas sensor cross-sensitivity
  • • Fall arrest indicator deployment
  • • Winch handle mechanism jam
Service: Sensor replacement per MSA schedule. Annual load test of tripod and winch.
Spares: MSA: Sicherheitsausrüstung per SOLAS-Mindestbestand. Lead time: 2-4 Wochen.