Ultrasonic Level Gauge
medium
90 Modelle gesamt
Known Models (90)
⚙️
Endress+Hauser Prosonic FMU30 5m non-Ex Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Endress+Hauser Prosonic FMU30 5m Ex ia Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU30 5m Ex d Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU30 10m non-Ex Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Endress+Hauser Prosonic FMU30 10m Ex ia Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU30 10m Ex d Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU30 15m non-Ex Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU30 15m Ex ia Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU30 15m Ex d Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU30 20m non-Ex Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU30 20m Ex ia Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU30 20m Ex d Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU30 25m non-Ex Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU30 25m Ex ia Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU30 25m Ex d Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Endress+Hauser Prosonic FMU30 30m non-Ex Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU30 30m Ex ia Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Endress+Hauser Prosonic FMU30 30m Ex d Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU40 5m non-Ex Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU40 5m Ex ia Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Endress+Hauser Prosonic FMU40 5m Ex d Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU40 10m non-Ex Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU40 10m Ex ia Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU40 10m Ex d Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Endress+Hauser Prosonic FMU40 15m non-Ex Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU40 15m Ex ia Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU40 15m Ex d Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU40 20m non-Ex Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU40 20m Ex ia Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU40 20m Ex d Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU40 25m non-Ex Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU40 25m Ex ia Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU40 25m Ex d Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Endress+Hauser Prosonic FMU40 30m non-Ex Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Endress+Hauser Prosonic FMU40 30m Ex ia Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU40 30m Ex d Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU44 5m non-Ex Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU44 5m Ex ia Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU44 5m Ex d Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU44 10m non-Ex Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU44 10m Ex ia Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU44 10m Ex d Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Endress+Hauser Prosonic FMU44 15m non-Ex Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU44 15m Ex ia Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU44 15m Ex d Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU44 20m non-Ex Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU44 20m Ex ia Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Endress+Hauser Prosonic FMU44 20m Ex d Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU44 25m non-Ex Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU44 25m Ex ia Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Endress+Hauser Prosonic FMU44 25m Ex d Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU44 30m non-Ex Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU44 30m Ex ia Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Endress+Hauser Prosonic FMU44 30m Ex d Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-M Marine 5m non-Ex Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-M Marine 5m Ex ia Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-M Marine 5m Ex d Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Musasino UTI-M Marine 10m non-Ex Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Musasino UTI-M Marine 10m Ex ia Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-M Marine 10m Ex d Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-M Marine 15m non-Ex Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-M Marine 15m Ex ia Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-M Marine 15m Ex d Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-M Marine 20m non-Ex Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Musasino UTI-M Marine 20m Ex ia Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-M Marine 20m Ex d Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-M Marine 25m non-Ex Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Musasino UTI-M Marine 25m Ex ia Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-M Marine 25m Ex d Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-M Marine 30m non-Ex Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-M Marine 30m Ex ia Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-M Marine 30m Ex d Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-C Chemical 5m non-Ex Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-C Chemical 5m Ex ia Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-C Chemical 5m Ex d Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-C Chemical 10m non-Ex Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Musasino UTI-C Chemical 10m Ex ia Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-C Chemical 10m Ex d Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-C Chemical 15m non-Ex Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-C Chemical 15m Ex ia Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-C Chemical 15m Ex d Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Musasino UTI-C Chemical 20m non-Ex Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-C Chemical 20m Ex ia Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-C Chemical 20m Ex d Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-C Chemical 25m non-Ex Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-C Chemical 25m Ex ia Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Musasino UTI-C Chemical 25m Ex d Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Musasino UTI-C Chemical 30m non-Ex Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Musasino UTI-C Chemical 30m Ex ia Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Musasino UTI-C Chemical 30m Ex d Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06