Float Level Switch
medium
90 Modelle gesamt
Known Models (90)
Honeywell Enraf BPM Portable 5m non-Ex Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf BPM Portable 5m Ex ia Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf BPM Portable 5m Ex d Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf BPM Portable 10m non-Ex Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf BPM Portable 10m Ex ia Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf BPM Portable 10m Ex d Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf BPM Portable 15m non-Ex Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf BPM Portable 15m Ex ia Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf BPM Portable 15m Ex d Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf BPM Portable 20m non-Ex Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Honeywell Enraf BPM Portable 20m Ex ia Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf BPM Portable 20m Ex d Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf BPM Portable 25m non-Ex Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf BPM Portable 25m Ex ia Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf BPM Portable 25m Ex d Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf BPM Portable 30m non-Ex Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf BPM Portable 30m Ex ia Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Honeywell Enraf BPM Portable 30m Ex d Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 5m non-Ex Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 5m Ex ia Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 5m Ex d Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 10m non-Ex Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 10m Ex ia Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 10m Ex d Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 15m non-Ex Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 15m Ex ia Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 15m Ex d Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Honeywell Enraf GPL Portable 20m non-Ex Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 20m Ex ia Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 20m Ex d Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 25m non-Ex Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 25m Ex ia Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 25m Ex d Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 30m non-Ex Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 30m Ex ia Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Honeywell Enraf GPL Portable 30m Ex d Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 5m non-Ex Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 5m Ex ia Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 5m Ex d Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 10m non-Ex Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 10m Ex ia Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Krohne BM26A 10m Ex d Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 15m non-Ex Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 15m Ex ia Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 15m Ex d Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 20m non-Ex Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 20m Ex ia Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 20m Ex d Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 25m non-Ex Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 25m Ex ia Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 25m Ex d Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Krohne BM26A 30m non-Ex Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 30m Ex ia Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM26A 30m Ex d Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Krohne BM70A 5m non-Ex Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Krohne BM70A 5m Ex ia Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM70A 5m Ex d Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM70A 10m non-Ex Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM70A 10m Ex ia Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM70A 10m Ex d Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM70A 15m non-Ex Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM70A 15m Ex ia Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM70A 15m Ex d Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM70A 20m non-Ex Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM70A 20m Ex ia Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM70A 20m Ex d Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM70A 25m non-Ex Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM70A 25m Ex ia Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM70A 25m Ex d Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM70A 30m non-Ex Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Krohne BM70A 30m Ex ia Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Krohne BM70A 30m Ex d Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Yokogawa PCTB Portable 5m non-Ex Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Yokogawa PCTB Portable 5m Ex ia Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Yokogawa PCTB Portable 5m Ex d Marine
measurement_range_m: 5
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Yokogawa PCTB Portable 10m non-Ex Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Yokogawa PCTB Portable 10m Ex ia Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Yokogawa PCTB Portable 10m Ex d Marine
measurement_range_m: 10
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Yokogawa PCTB Portable 15m non-Ex Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Yokogawa PCTB Portable 15m Ex ia Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Yokogawa PCTB Portable 15m Ex d Marine
measurement_range_m: 15
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Yokogawa PCTB Portable 20m non-Ex Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Yokogawa PCTB Portable 20m Ex ia Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Yokogawa PCTB Portable 20m Ex d Marine
measurement_range_m: 20
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Yokogawa PCTB Portable 25m non-Ex Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Yokogawa PCTB Portable 25m Ex ia Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Yokogawa PCTB Portable 25m Ex d Marine
measurement_range_m: 25
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Yokogawa PCTB Portable 30m non-Ex Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: non-Ex
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
⚙️
Yokogawa PCTB Portable 30m Ex ia Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex ia
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06
Yokogawa PCTB Portable 30m Ex d Marine
measurement_range_m: 30
accuracy_mm: 3.0
atex_zone: Ex d
output: 4-20mA HART
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22T23:45:06