Open Loop Scrubber
medium
Open-loop seawater scrubber systems
Known Models (2)
Alfa Laval PureSOx Open Loop
variable
· Exhaust Gas Treatment
· open_loop
type: open_loop
marpol: True
Common Failures:
- • Tower internal erosion
- • Water treatment unit failure
- • Emission monitoring malfunction
Service: PureSOx brand. Open-loop mode. Washwater treatment required.
Spares: Alfa Laval: Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
Wärtsilä Wartsila Open Loop Scrubber
sized per engine power
· Exhaust Gas Treatment
· open_loop
type: open_loop
marpol: True
Common Failures:
- • Scrubber tower corrosion
- • Seawater pump failure
- • pH monitoring drift
- • Nozzle blockage
Service: Open-loop uses seawater. Restricted in some ports/ECAs. Washwater monitoring mandatory.