OS
← Ballast Water Treatment Systems

Electrolysis BWTS

medium
Ballast water treatment using electrochlorination/electrolysis

Known Models (6)

Ecochlor Ecochlor BWTS
Ecochlor Ecochlor BWTS
variable · Ballast Water Treatment · chlorine_dioxide
type: chlorine_dioxide
imo_approved: True
Common Failures:
  • • ClO2 generator failure
  • • Chemical supply depletion
  • • Neutralization imbalance
  • • Dosing pump failure
Service: Chlorine dioxide chemical treatment. Chemical resupply required.
Spares: Ecochlor: UV-Lampen an Bord vorhalten (2 Sätze). Filterelemente: 1 Satz. Lead time: 2-4 Wochen.
JFE Engineering BallastAce BWTS
JFE Engineering BallastAce BWTS
variable · Ballast Water Treatment · electrolysis
type: electrolysis
imo_approved: True
origin: Japan
Common Failures:
  • • Electrode degradation
  • • Electrolysis cell scaling
  • • Control system failure
Service: Japanese manufacturer. Electrode life monitoring.
Spares: JFE Engineering: UV-Lampen an Bord vorhalten (2 Sätze). Filterelemente: 1 Satz. Lead time: 2-4 Wochen.
NK Company NK Balclor BWTS
NK Company NK Balclor BWTS
variable · Ballast Water Treatment · electrolysis
type: electrolysis
imo_approved: True
origin: Korea
Common Failures:
  • • Electrode erosion
  • • TRO sensor drift
  • • Power supply failure
  • • Hydrogen gas ventilation issue
Service: Korean manufacturer. Monitor hydrogen generation during electrolysis.
Spares: NK Company: UV-Lampen an Bord vorhalten (2 Sätze). Filterelemente: 1 Satz. Lead time: 2-4 Wochen.
Panasonic (GS-YUASA) Panasonic Marine BWTS
Panasonic (GS-YUASA) Panasonic Marine BWTS
variable · Ballast Water Treatment · electrolysis
type: electrolysis
origin: Japan
Common Failures:
  • • Electrode failure
  • • Control board malfunction
  • • TRO measurement error
Service: Japanese electronics manufacturer entering marine. Electrode service.
Spares: Panasonic (GS-YUASA): UV-Lampen an Bord vorhalten (2 Sätze). Filterelemente: 1 Satz. Lead time: 2-4 Wochen.
Samsung Heavy Industries PureSeas BWTS
Samsung Heavy Industries PureSeas BWTS
variable · Ballast Water Treatment · electrolysis
type: electrolysis
imo_approved: True
origin: Korea
Common Failures:
  • • Electrode wear
  • • TRO sensor failure
  • • Power module malfunction
Service: Korean shipyard product. Electrode replacement schedule.
Spares: Samsung Heavy Industries: UV-Lampen an Bord vorhalten (2 Sätze). Filterelemente: 1 Satz. Lead time: 2-4 Wochen.
Techcross Techcross ECS BWTS
Techcross Techcross ECS BWTS
variable · Ballast Water Treatment · electrolysis
type: electrolysis
imo_approved: True
uscg_approved: True
origin: Korea
Common Failures:
  • • Electrode erosion
  • • TRO sensor calibration drift
  • • Power supply failure
  • • Neutralization system malfunction
Service: Korean manufacturer, largest BWTS market share. Electrode replacement per wear. TRO monitoring.
Spares: Techcross: UV-Lampen an Bord vorhalten (2 Sätze). Filterelemente: 1 Satz. Lead time: 2-4 Wochen.