Fixed Gas Detector
medium
16 Modelle gesamt
Fixed/installed gas detection for continuous monitoring
9 Hersteller · 16 Modelle
🏭
Dräger
6 ✓ 6 verifiziert⚙️
Polytron 8000
✓ verifiziert
Inspector
1 gas per point
· Hazardous Gas Detection
· fixed
type: fixed
output: 4-20mA
solas: True
Common Failures:
- • Sensor poisoning
- • 4-20mA signal drift
- • Sensor housing corrosion
- • Calibration gas port blockage
Service: Fixed installation in pump rooms, cargo areas. Calibrate every 6 months.
Spares: Dräger: Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
⚙️
PIR 7000
✓ verifiziert
Inspector
HC detection
· Hazardous Gas Detection
· fixed
type: fixed
sensor: NDIR
solas: True
Common Failures:
- • IR source degradation
- • Window contamination
- • Electronics failure
Service: No sensor poisoning (IR). Extended calibration intervals. Clean window annually.
Spares: Dräger: Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
⚙️
Dräger Polytron 5000
✓ verifiziert
equipment_type: fixed_gas_detector
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.8
series: Polytron
model_code: Polytron 5000
Fixed gas detector — fixed point detector
⚙️
Dräger Polytron 7000
✓ verifiziert
equipment_type: fixed_gas_detector
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.8
series: Polytron
model_code: Polytron 7000
Fixed gas detector — fixed transmitter
⚙️
Dräger Polytron 8000
✓ verifiziert
equipment_type: fixed_gas_detector
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.8
series: Polytron
model_code: Polytron 8000
Fixed gas detector — fixed IR
⚙️
Dräger PIR 7200
✓ verifiziert
equipment_type: fixed_gas_detector
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.8
series: PIR
model_code: PIR 7200
Fixed gas detector — open path IR
🏭
Honeywell
3 ✓ 3 verifiziert⚙️
Searchline Excel
✓ verifiziert
Inspector
0-5 LEL·m
· Hazardous Gas Detection
· fixed
type: fixed
sensor: open_path_IR
Common Failures:
- • Source/detector misalignment
- • Window fouling
- • Electronics aging
Service: Open-path for fence-line and perimeter detection
Spares: Honeywell: Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
⚙️
Honeywell Sensepoint XCL
✓ verifiziert
equipment_type: fixed_gas_detector
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.75
model_code: Sensepoint XCL
Fixed gas detector — fixed point gas transmitter
⚙️
Honeywell Searchzone Sonik
✓ verifiziert
equipment_type: fixed_gas_detector
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-16
confidence: 0.75
model_code: Searchzone Sonik
Fixed gas detector — ultrasonic leak detector
🏭
Crowcon
1 ✓ 1 verifiziert⚙️
Xgard Bright Fixed
✓ verifiziert
Inspector
1 gas per point
· Hazardous Gas Detection
· fixed
type: fixed
output: 4-20mA
display: True
Common Failures:
- • Sensor end-of-life
- • Display failure
- • 4-20mA output drift
Service: UK manufacturer. OLED display shows gas reading at point.
Spares: Crowcon: Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
🏭
Det-Tronics
1 ✓ 1 verifiziert⚙️
FlexSight LS2000
✓ verifiziert
Inspector
0-5 LEL·m
· Hazardous Gas Detection
· fixed
type: fixed
sensor: open_path_IR
Common Failures:
- • Optical alignment drift
- • Window contamination
- • Heater failure in cold
Service: Open-path detection for large areas. Re-align optics after maintenance.
Spares: Det-Tronics: Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
🏭
GfG Instrumentation
1 ✓ 1 verifiziert⚙️
EC 28 Fixed Transmitter
✓ verifiziert
Inspector
1 gas per point
· Hazardous Gas Detection
· fixed
type: fixed
output: 4-20mA
origin: Germany
Common Failures:
- • Sensor depletion
- • 4-20mA signal loss
- • Housing seal failure
Service: German manufacturer. Wide range of toxic gas sensors available.
Spares: GfG Instrumentation: Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
🏭
Honeywell (RAE)
1 ✓ 1 verifiziert⚙️
FGD-1000 Fixed PID
✓ verifiziert
Inspector
VOC detection
· Hazardous Gas Detection
· fixed
type: fixed
sensor: PID
application: chemical_cargo
Common Failures:
- • PID lamp burnout
- • Window contamination
- • Electronics drift
Service: For cargo pump rooms with chemical cargoes. PID lamp replacement.
Spares: Honeywell (RAE): Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
🏭
MSA
1 ✓ 1 verifiziert⚙️
Ultima X5000
✓ verifiziert
Inspector
1 gas per point
· Hazardous Gas Detection
· fixed
type: fixed
sil: 2
output: 4-20mA/HART
Common Failures:
- • Sensor drift
- • Relay failure
- • Display electronics
- • Housing seal degradation
Service: SIL2 rated for safety-critical applications. HART protocol.
Spares: MSA: Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
🏭
Oldham (3M/Teledyne)
1 ✓ 1 verifiziert⚙️
OLCT 200 Fixed
✓ verifiziert
Inspector
1 gas per point
· Hazardous Gas Detection
· fixed
type: fixed
output: 4-20mA/Modbus
Common Failures:
- • Sensor degradation
- • Communication fault
- • Housing corrosion
Service: Teledyne product. Modbus and 4-20mA output.
Spares: Oldham (3M/Teledyne): Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.
🏭
Simtronics
1 ✓ 1 verifiziert⚙️
GD10P
✓ verifiziert
Inspector
HC detection
· Hazardous Gas Detection
· fixed
type: fixed
sensor: point_IR
Common Failures:
- • IR optics contamination
- • Heater element failure
- • Signal drift
Service: Autronica/Simtronics product. Common on offshore platforms.
Spares: Simtronics: Spezialteile per Hersteller. Lead time: 4-8 Wochen. Gasdetektions-Sensoren an Bord.