OS
← Breathing Apparatus

SCBA

medium
Self-Contained Breathing Apparatus for firefighting

Known Models (11)

Dräger PSS 5000
Dräger PSS 5000
30 min at moderate work · Compressed Air (Breathing) · scba
type: scba
cylinder_l: 6.8
pressure_bar: 300
duration_min: 30
solas: True
Common Failures:
  • • Mask seal degradation
  • • Cylinder valve O-ring leak
  • • Demand valve diaphragm failure
  • • Pressure gauge inaccuracy
Service: Annual service by certified technician. Cylinder hydrostatic test every 5 years. Mask fit test annually.
Spares: Dräger: Ersatz-Masken, Atemluftflaschen und Prüf-Kits an Bord vorhalten. Lead time: 1-3 Wochen.
Dräger PSS 3000
Dräger PSS 3000
30 min · Compressed Air (Breathing) · scba
type: scba
cylinder_l: 6.8
pressure_bar: 300
solas: True
Common Failures:
  • • Mask strap deterioration
  • • Demand valve failure
  • • Cylinder valve leak
Service: Budget SCBA option. Same service intervals as PSS 5000.
Spares: Dräger: Ersatz-Masken, Atemluftflaschen und Prüf-Kits an Bord vorhalten. Lead time: 1-3 Wochen.
Dräger PSS AirBoss
Dräger PSS AirBoss
45 min with 9L cylinder · Compressed Air (Breathing) · scba
type: scba
cylinder_l: 9
pressure_bar: 300
solas: True
hud: True
Common Failures:
  • • Electronics module failure
  • • HUD display malfunction
  • • Cylinder valve issue
Service: High-end SCBA with integrated electronics. Annual service mandatory.
Spares: Dräger: Ersatz-Masken, Atemluftflaschen und Prüf-Kits an Bord vorhalten. Lead time: 1-3 Wochen.
Dräger PSS 7000
Dräger PSS 7000
45 min with 9L cylinder · Compressed Air (Breathing) · scba
type: scba
cylinder_l: 9
pressure_bar: 300
telemetry: True
solas: True
Common Failures:
  • • Telemetry transmitter failure
  • • Cylinder valve O-ring leak
  • • Demand valve freeze
Service: Top-tier SCBA with wireless telemetry to base station. Annual service.
Spares: Dräger: Ersatz-Masken, Atemluftflaschen und Prüf-Kits an Bord vorhalten. Lead time: 1-3 Wochen.
Honeywell Cougar SCBA
Honeywell Cougar SCBA
30 min · Compressed Air (Breathing) · scba
type: scba
solas: True
Common Failures:
  • • Demand valve diaphragm failure
  • • Harness buckle wear
  • • Cylinder retention issue
Service: Honeywell Safety product. Annual service mandatory.
Spares: Honeywell: Ersatz-Masken, Atemluftflaschen und Prüf-Kits an Bord vorhalten. Lead time: 1-3 Wochen.
Interspiro Incurve SCBA
Interspiro Incurve SCBA
30 min · Compressed Air (Breathing) · scba
type: scba
solas: True
origin: Sweden
Common Failures:
  • • Demand valve failure
  • • Mask communication device failure
  • • Cylinder valve leak
Service: Swedish manufacturer. Common on Scandinavian fleet.
Spares: Interspiro: Ersatz-Masken, Atemluftflaschen und Prüf-Kits an Bord vorhalten. Lead time: 1-3 Wochen.
MSA G1 SCBA
MSA G1 SCBA
30 min · Compressed Air (Breathing) · scba
type: scba
cylinder_l: 6.8
pressure_bar: 300
solas: True
Common Failures:
  • • Mask lens fogging
  • • Demand valve freeze in cold
  • • Electronics failure
  • • Cylinder gauge inaccuracy
Service: Premium SCBA. Optional thermal imaging camera. Annual service.
Spares: MSA: Ersatz-Masken, Atemluftflaschen und Prüf-Kits an Bord vorhalten. Lead time: 1-3 Wochen.
MSA AirMaXX SCBA
MSA AirMaXX SCBA
30 min · Compressed Air (Breathing) · scba
type: scba
solas: True
Common Failures:
  • • Demand valve diaphragm wear
  • • Mask seal degradation
  • • Harness buckle failure
Service: Lightweight design for extended use. Annual service.
Spares: MSA: Ersatz-Masken, Atemluftflaschen und Prüf-Kits an Bord vorhalten. Lead time: 1-3 Wochen.
MSA AirGo Pro SCBA
MSA AirGo Pro SCBA
30 min · Compressed Air (Breathing) · scba
type: scba
solas: True
Common Failures:
  • • Regulator first-stage failure
  • • Cylinder retention mechanism
  • • Low-pressure alarm malfunction
Service: Ergonomic harness system. Annual full service.
Spares: MSA: Ersatz-Masken, Atemluftflaschen und Prüf-Kits an Bord vorhalten. Lead time: 1-3 Wochen.
MSA M1 SCBA
MSA M1 SCBA
30 min · Compressed Air (Breathing) · scba
type: scba
solas: True
Common Failures:
  • • Mask seal deterioration
  • • Regulator first-stage failure
  • • Battery for alarm
Service: Budget SCBA option. Same service intervals as premium models.
Spares: MSA: Ersatz-Masken, Atemluftflaschen und Prüf-Kits an Bord vorhalten. Lead time: 1-3 Wochen.
Scott Safety (Tyco) ACSi SCBA
Scott Safety (Tyco) ACSi SCBA
30 min · Compressed Air (Breathing) · scba
type: scba
solas: True
Common Failures:
  • • Mask seal wear
  • • PASS device battery failure
  • • Regulator freeze
Service: 3M/Scott product. Annual service by certified tech.
Spares: Scott Safety (Tyco): Ersatz-Masken, Atemluftflaschen und Prüf-Kits an Bord vorhalten. Lead time: 1-3 Wochen.