Shaft Generator / PTO
high
64 Modelle gesamt
Power take-off generator driven by the main engine shaft for electrical power generation at sea.
25 yr
Typical Lifetime
Typical Manufacturers
ABB
Siemens
Hyundai
WEG
28 Hersteller · 64 Modelle
🏭
Caterpillar / MaK
15 ✓ 7 verifiziert
C7.1 Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 150.0 kW
· Diesel/MDO/MGO
engine_model: C7.1
cylinders: 6
configuration: inline
displacement_l: 7.01
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MDO', 'MGO']
application: marine generator set
Common Failures:
- • Aftercooler fouling causing high charge-air temperature
- • Injector wear causing hard starting and smoke
- • Raw-water pump seal leakage on seawater-cooled installations
Service: Follow Caterpillar marine maintenance schedule. Typical routine service includes engine oil and filter change around 250-500 operating hours depending on duty and oil analysis; valve lash inspection at scheduled interval; cooling system and aftercooler inspection periodically.
Spares: Keep oil filters, fuel filters, seawater pump impeller or kit, belts, thermostat, injector sealing kits and starter/alternator spares depending on vessel redundancy.
⚙️
C9.3 Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 250.0 kW
· Diesel/MDO/MGO
engine_model: C9.3
cylinders: 6
configuration: inline
displacement_l: 9.3
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MDO', 'MGO']
application: marine generator set
Common Failures:
- • Fuel injector wear causing uneven exhaust temperatures
- • Turbocharger fouling from prolonged low-load operation
- • Heat exchanger fouling causing high jacket-water temperature
Service: Routine maintenance normally includes oil, fuel filter and coolant checks at manufacturer-defined hour intervals; avoid prolonged low-load running and perform load checks under operating conditions.
Spares: Recommended onboard spares include filter sets, belts, seawater pump kit, injector seals, sensors and starter motor for critical applications.
⚙️
C18 ACERT Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 550.0 kW
· Diesel/MDO/MGO
engine_model: C18 ACERT
cylinders: 6
configuration: inline
displacement_l: 18.1
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MDO', 'MGO']
application: marine generator set
Common Failures:
- • Charge-air cooler fouling causing high exhaust temperature
- • Injector tip deposits after poor fuel quality
- • Turbocharger turbine fouling after extended low-load operation
Service: Operate periodically at sufficient load to reduce wet stacking. Carry out oil and filter changes, valve adjustment and aftercooler inspection according to Caterpillar marine service schedule.
Spares: Keep fuel injectors or injector kits according to criticality, filter sets, turbocharger service kit, seawater pump kit, belts and key electronic sensors.
⚙️
C32 ACERT Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 940.0 kW
· Diesel/MDO/MGO
engine_model: C32 ACERT
cylinders: 12
configuration: V
displacement_l: 32.1
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MDO', 'MGO']
application: marine generator set
Common Failures:
- • Injector wear causing cylinder imbalance
- • Turbocharger fouling under low-load operation
- • Cooling package fouling causing derating or shutdown
Service: Follow Caterpillar planned maintenance. Typical shipboard practice includes daily level and leak checks, periodic load testing, oil sampling and scheduled valve lash and injector inspection.
Spares: Keep full filter service kits, seawater pump components, belts, sensors, starter spares and selected injector components where vessel redundancy is limited.
3508B Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 968.0 kW
· Diesel/MDO
engine_model: 3508B
cylinders: 8
configuration: V
displacement_l: 34.5
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MDO']
application: marine generator set
Common Failures:
- • Cylinder head cracking or valve seat wear in high-hour engines
- • Turbocharger fouling and bearing wear
- • Fuel nozzle wear causing high exhaust temperature spread
Service: Daily checks include oil pressure, jacket-water temperature and exhaust temperature spread. Major component inspection is normally planned by running hours and condition monitoring, with oil analysis strongly recommended.
Spares: Maintain filters, fuel nozzles, injector components, exhaust manifold gaskets, turbocharger kits, water pump kits and selected cylinder head spares for remote operation.
3512B Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 1360.0 kW
· Diesel/MDO
engine_model: 3512B
cylinders: 12
configuration: V
displacement_l: 51.8
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MDO']
application: marine generator set
Common Failures:
- • Injector and nozzle wear causing exhaust temperature deviation
- • Aftercooler fouling or leakage
- • Turbocharger fouling and oil leakage at high running hours
Service: Use oil analysis and exhaust temperature trending. Scheduled maintenance includes oil and filter service, valve lash checks, fuel system checks and cooling system cleaning at manufacturer-defined intervals.
Spares: Keep service kits, filters, nozzle sets, gaskets, turbocharger cartridge or overhaul kit, jacket-water pump kit and critical sensors.
3516B Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 1825.0 kW
· Diesel/MDO
engine_model: 3516B
cylinders: 16
configuration: V
displacement_l: 69.0
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MDO']
application: marine generator set
Common Failures:
- • Fuel nozzle wear leading to high exhaust temperatures
- • Charge-air cooler fouling
- • Turbocharger bearing and seal wear in high-hour service
Service: Plan maintenance by Caterpillar hour schedule and condition monitoring. For standby units, run monthly load tests and avoid continuous light-load operation.
Spares: Critical spares include fuel nozzles, filters, gaskets, jacket-water and seawater pump kits, turbocharger service parts and engine control sensors.
⚙️
Caterpillar 3508 Marine Generator Set
source: Caterpillar Marine
model_number: 3508 GenSet
⚙️
Caterpillar 3512 Marine Generator Set
source: Caterpillar Marine
model_number: 3512 GenSet
⚙️
Caterpillar 3516 Marine Generator Set
source: Caterpillar Marine
model_number: 3516 GenSet
⚙️
Caterpillar C7.1 Marine Generator Set
source: Caterpillar Marine
model_number: C7.1 GenSet
⚙️
Caterpillar C9.3 Marine Generator Set
source: Caterpillar Marine
model_number: C9.3 GenSet
⚙️
Caterpillar C18 Marine Generator Set
source: Caterpillar Marine
model_number: C18 GenSet
⚙️
Caterpillar C32 Marine Generator Set
source: Caterpillar Marine
model_number: C32 GenSet
⚙️
Caterpillar C175-16 Marine Generator Set
source: Caterpillar Marine
model_number: C175-16 GenSet
🏭
Cummins
8 ✓ 8 verifiziert⚙️
6BT5.9-DM Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 92.0 kW
· Diesel/MDO/MGO
engine_model: 6BT5.9-DM
cylinders: 6
configuration: inline
displacement_l: 5.9
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MDO', 'MGO']
application: marine generator drive
Common Failures:
- • Raw-water pump impeller damage
- • Injector pump leakage or governor instability on older units
- • Heat exchanger fouling causing overheating
Service: Routine service normally includes oil and filter change around 250 hours, fuel filter replacement, belt inspection and cooling circuit inspection. Load-test periodically.
Spares: Keep fuel filters, oil filters, impeller kit, belts, thermostat, injector pipes and starter motor where single generator redundancy is limited.
⚙️
6CTA8.3-DM Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 175.0 kW
· Diesel/MDO/MGO
engine_model: 6CTA8.3-DM
cylinders: 6
configuration: inline
displacement_l: 8.3
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MDO', 'MGO']
application: marine generator drive
Common Failures:
- • Aftercooler fouling causing high exhaust temperature
- • Turbocharger oil leakage after high-hour service
- • Fuel injector wear causing smoke and rough running
Service: Daily checks include oil, coolant, leaks and exhaust temperature. Perform oil/filter and fuel filter service at Cummins recommended intervals; inspect aftercooler and heat exchanger periodically.
Spares: Recommended spares include filters, impeller kit, belts, injector seals, thermostats and turbocharger gasket kit.
⚙️
QSM11-DM Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 317.0 kW
· Diesel/MGO
engine_model: QSM11-DM
cylinders: 6
configuration: inline
displacement_l: 10.8
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MGO']
application: marine generator drive
Common Failures:
- • Injector wear causing misfire and exhaust temperature spread
- • Turbocharger fouling from low-load operation
- • Heat exchanger scaling in seawater service
Service: Use trend monitoring for exhaust temperatures and oil analysis. Conduct oil/filter changes and valve adjustment according to Cummins marine schedule.
Spares: Recommended spares include filter sets, injector seals, seawater pump kits, belts, sensors and turbocharger gasket sets.
⚙️
KTA19-DM Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 448.0 kW
· Diesel/MDO
engine_model: KTA19-DM
cylinders: 6
configuration: inline
displacement_l: 19.0
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MDO']
application: marine generator drive
Common Failures:
- • Injector and PT fuel system wear causing unstable load sharing
- • Turbocharger fouling and oil leakage
- • Liner cavitation risk if coolant treatment is neglected
Service: Maintain coolant treatment and carry out oil analysis. Scheduled maintenance includes oil/filter service, valve and injector setting, turbocharger inspection and cooling system checks.
Spares: Keep PT fuel system service parts, injector sets, filter kits, coolant treatment chemicals, water pump kit and turbocharger service kit.
⚙️
QSB7-DM Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 195.0 kW
· Diesel/MGO
engine_model: QSB7-DM
cylinders: 6
configuration: inline
displacement_l: 6.7
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MGO']
application: marine generator drive
Common Failures:
- • Electronic sensor faults causing alarms or derating
- • Seawater pump seal leakage
- • Injector fouling after contaminated fuel
Service: Follow Cummins marine maintenance schedule. Regular oil sampling, filter changes and seawater circuit checks are recommended; run at adequate load to avoid wet stacking.
Spares: Keep ECM sensors, filters, belts, seawater pump kit, injector seals and common electrical spares.
⚙️
QSL9-DM Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 264.0 kW
· Diesel/MGO
engine_model: QSL9-DM
cylinders: 6
configuration: inline
displacement_l: 8.9
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MGO']
application: marine generator drive
Common Failures:
- • Charge-air cooler fouling
- • Injector leakage or poor spray pattern
- • Cooling circuit fouling causing high temperature trips
Service: Perform scheduled oil, filter and valve train service according to Cummins manual. Periodic load-bank testing is recommended for standby or lightly loaded units.
Spares: Keep filters, belts, pump service kits, coolant hoses, injector seals, sensors and starter motor spares.
⚙️
KTA38-DM Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 880.0 kW
· Diesel/MDO
engine_model: KTA38-DM
cylinders: 12
configuration: V
displacement_l: 37.8
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MDO']
application: marine generator drive
Common Failures:
- • Cylinder head gasket leakage on high-hour units
- • Turbocharger fouling from poor combustion
- • Fuel injector wear causing high exhaust temperature deviation
Service: Daily checks should include crankcase oil level, coolant, fuel leaks and exhaust temperature spread. Follow Cummins schedule for valve/injector setting and major overhaul planning.
Spares: Carry filters, injector components, cylinder head gaskets, water pump repair kit, turbocharger kit and critical sensors.
⚙️
KTA50-DM Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 1100.0 kW
· Diesel/MDO
engine_model: KTA50-DM
cylinders: 16
configuration: V
displacement_l: 50.3
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MDO']
application: marine generator drive
Common Failures:
- • Injector wear causing exhaust temperature spread
- • Turbocharger seal leakage
- • Cooling system fouling causing high jacket-water temperature
Service: Plan oil sampling and valve/injector setting by running hours. Avoid prolonged low-load running; perform load tests and cooling system cleaning periodically.
Spares: Recommended spares include filter sets, injector and PT pump service parts, turbocharger kits, water pump kit, gaskets and sensors.
🏭
MTU
5 ✓ 5 verifiziert⚙️
Series 60 Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 300.0 kW
· Diesel/MGO
engine_model: MTU Series 60
cylinders: 6
configuration: inline
displacement_l: 14.0
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MGO']
application: marine generator set
Common Failures:
- • Injector and electronic control faults on high-hour units
- • Turbocharger fouling
- • Cooling system fouling causing high temperature alarms
Service: Follow MTU maintenance schedule. Regular service includes oil and filter changes, valve adjustment, coolant checks and periodic load testing.
Spares: Keep filter kits, injector seals, sensors, belts, water pump components and starter motor spares.
12V 2000 M41A Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 760.0 kW
· Diesel/MGO
engine_model: 12V 2000 M41A
cylinders: 12
configuration: V
displacement_l: None
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MGO']
application: marine generator set
Common Failures:
- • Injector faults causing rough running
- • Charge-air cooler fouling
- • Coolant leakage at hose and gasket joints
Service: Follow MTU running-hour service plan. Routine maintenance includes oil and filter service, valve clearance checks, coolant testing and electronic diagnostics.
Spares: Keep MTU filter kits, sensors, belts, injector sealing kits, coolant hoses and starter motor spares.
⚙️
16V 2000 M41A Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 1000.0 kW
· Diesel/MGO
engine_model: 16V 2000 M41A
cylinders: 16
configuration: V
displacement_l: None
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MGO']
application: marine generator set
Common Failures:
- • Turbocharger fouling after light-load service
- • Injector wear causing cylinder imbalance
- • Sensor faults causing alarm or derating
Service: Carry out oil/filter service and ECU diagnostics according to MTU intervals. Avoid extended no-load or very low-load operation.
Spares: Recommended spares include filter sets, injector seals, coolant hoses, belts, turbocharger gaskets and electronic sensors.
⚙️
12V 4000 M23S Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 1650.0 kW
· Diesel/MGO
engine_model: 12V 4000 M23S
cylinders: 12
configuration: V
displacement_l: None
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MGO']
application: marine generator set
Common Failures:
- • Injector faults causing exhaust temperature deviation
- • Turbocharger fouling
- • Charge-air cooler contamination
Service: Follow MTU service schedule with oil analysis, valve checks, filter changes and scheduled major component inspections.
Spares: Keep filter kits, injector service parts, sensors, coolant pump parts, belts and turbocharger gasket sets.
⚙️
16V 4000 M23S Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 2200.0 kW
· Diesel/MGO
engine_model: 16V 4000 M23S
cylinders: 16
configuration: V
displacement_l: None
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MGO']
application: marine generator set
Common Failures:
- • Turbocharger fouling under low-load profile
- • Injector wear causing uneven cylinder load
- • Cooling system fouling causing high temperature derating
Service: Use MTU service schedule and diagnostics. Routine maintenance includes oil/filter changes, coolant testing, valve checks and periodic load-bank testing.
Spares: Recommended spares include MTU filter kits, injector seals, sensors, starter spares, cooling pump kit and turbocharger service parts.
🏭
John Deere
4 ✓ 4 verifiziert⚙️
4045TFM85 Marine Generator Drive
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 74.0 kW
· Diesel/MGO
engine_model: 4045TFM85
cylinders: 4
configuration: inline
displacement_l: 4.5
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MGO']
application: marine generator drive
Common Failures:
- • Raw-water pump impeller failure
- • Injector fouling from contaminated fuel
- • Heat exchanger scaling
Service: Follow John Deere marine maintenance schedule. Routine service includes oil and filter changes, fuel filter service, belt inspection and cooling system checks.
Spares: Keep oil and fuel filters, impeller kit, belts, thermostat, injector seals and starter spares.
⚙️
6068AFM85 Marine Generator Drive
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 150.0 kW
· Diesel/MGO
engine_model: 6068AFM85
cylinders: 6
configuration: inline
displacement_l: 6.8
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MGO']
application: marine generator drive
Common Failures:
- • Injector wear causing smoke
- • Turbocharger fouling
- • Cooling water pump leakage
Service: Carry out oil/filter service, fuel filter replacement and cooling system inspection according to John Deere intervals. Periodic load testing is recommended.
Spares: Recommended spares include filters, impeller kit, belts, injectors or seals, thermostats and coolant hoses.
⚙️
6090AFM85 Marine Generator Drive
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 242.0 kW
· Diesel/MGO
engine_model: 6090AFM85
cylinders: 6
configuration: inline
displacement_l: 9.0
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MGO']
application: marine generator drive
Common Failures:
- • Aftercooler fouling
- • Injector wear
- • Electronic sensor faults causing alarms
Service: Follow John Deere marine schedule. Routine checks include oil level, coolant, fuel leaks, exhaust temperature trend and periodic ECU diagnostics.
Spares: Keep filters, belts, seawater pump kit, sensor spares, injector seals and thermostat kit.
⚙️
6135AFM85 Marine Generator Drive
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 350.0 kW
· Diesel/MGO
engine_model: 6135AFM85
cylinders: 6
configuration: inline
displacement_l: 13.5
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel', 'MGO']
application: marine generator drive
Common Failures:
- • Turbocharger fouling from light-load operation
- • Injector leakage or poor spray pattern
- • Cooling system fouling causing high temperature alarm
Service: Use periodic load testing and oil analysis. Follow John Deere intervals for oil/filter changes, valve lash checks and cooling system maintenance.
Spares: Recommended spares include filter kits, belts, water pump kit, injector seals, sensors and turbocharger gasket kit.
🏭
MacGregor
2 ✓ 2 verifiziert⚙️
Twistlock CV-20 Forged Shaft, Twistlock CV-20L Lifting Forged Shaft
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· Electrical Power Generation
source: dnv-approval-finder
Common Failures:
- • Generatorwicklung-Isolationsdegradation
- • AVR Spannungsregler-Fehlfunktion
- • Kupplung Schwingungsdämpfer Verschleiß
- • Gleichstrommaschine Bürstenverschleiß
Service: Generator-Isolationstest jährlich. AVR-Kalibrierung jährlich. Kupplung-Inspektion alle 5 Jahre. Ölwechsel per Herstellerangabe.
Spares: Ersatzteile über MacGregor Finland Oy oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
⚙️
Twistlock CV-20G Forged Shaft, Twistlock CV-20G Lifting Forged Shaft
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· Electrical Power Generation
source: dnv-approval-finder
Common Failures:
- • Generatorwicklung-Isolationsdegradation
- • AVR Spannungsregler-Fehlfunktion
- • Kupplung Schwingungsdämpfer Verschleiß
- • Gleichstrommaschine Bürstenverschleiß
Service: Generator-Isolationstest jährlich. AVR-Kalibrierung jährlich. Kupplung-Inspektion alle 5 Jahre. Ölwechsel per Herstellerangabe.
Spares: Ersatzteile über MacGregor Finland Oy oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
🏭
Northern Lights
2 ✓ 2 verifiziert⚙️
M944W Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 20.0 kW
· Diesel
engine_model: M944W
cylinders: 4
configuration: inline
displacement_l: None
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel']
application: marine generator set
Common Failures:
- • Raw-water pump impeller damage
- • Heat exchanger fouling
- • Fuel lift pump or injector wear on high-hour units
Service: Follow Northern Lights maintenance schedule. Routine tasks include oil/filter change, fuel filter change, impeller inspection and valve adjustment at specified hours.
Spares: Keep impeller kit, filters, belts, zincs if fitted, thermostat, fuel lift pump and starter spares.
⚙️
M1066 Series Marine Generator Set
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 80.0 kW
· Diesel
engine_model: M1066
cylinders: 6
configuration: inline
displacement_l: None
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel']
application: marine generator set
Common Failures:
- • Raw-water pump leakage
- • Heat exchanger scaling
- • Injector wear causing smoke
Service: Routine service includes oil/filter changes, fuel filters, belt checks, impeller replacement and valve adjustment according to Northern Lights schedule.
Spares: Keep filters, impeller kit, belts, injectors or nozzles, thermostat, hoses and starter motor spares.
🏭
ABB
1 ✓ 1 verifiziert⚙️
ABB Shaft Generator AMG
✓ verifiziert
source: llm_reference_catalog
needs_verification: True
catalog_added_at: 2026-05-22 14:11:11
confidence: 0.8
note: shaft_generator
🏭
Beta Marine
1 ✓ 1 verifiziert⚙️
BetaGen 10 Marine Generator
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 7.0 kW
· Diesel
engine_model: None
cylinders: None
configuration: None
displacement_l: None
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel']
application: marine generator set
Common Failures:
- • Raw-water impeller failure
- • Heat exchanger fouling
- • Alternator bearing wear
Service: Typical routine service includes oil/filter change, fuel filter change, seawater pump inspection and belt tension check according to Beta Marine schedule.
Spares: Keep impeller kit, filters, belts, zinc anodes where fitted, thermostat and alternator bearings depending on operating area.
🏭
Cummins Onan
1 ✓ 1 verifiziert⚙️
MDKDN Marine Generator
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 13.0 kW
· Diesel
engine_model: None
cylinders: None
configuration: None
displacement_l: None
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel']
application: marine generator set
Common Failures:
- • Raw-water pump impeller failure
- • Heat exchanger fouling
- • Control board or sensor faults in humid spaces
Service: Follow Cummins Onan marine service schedule. Routine maintenance includes oil and filter changes, fuel filter service, impeller inspection and periodic load run.
Spares: Keep impeller kit, oil and fuel filters, belts, zincs if fitted, control fuses and starter solenoid.
🏭
Fischer Panda
1 ✓ 1 verifiziert⚙️
Panda 15000i PMS Marine Generator
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 12.0 kW
· Diesel
engine_model: None
cylinders: None
configuration: None
displacement_l: None
rpm: None
frequency_hz: 50
fuel_types: ['Diesel']
application: marine generator set
Common Failures:
- • Seawater pump impeller failure
- • Exhaust elbow corrosion
- • Inverter/control faults on variable-speed units
Service: Service oil, fuel filters, seawater impeller and coolant circuit according to Fischer Panda interval schedule. Check exhaust water injection and anti-siphon arrangement regularly.
Spares: Keep impeller kit, filters, belts, glow plugs, exhaust temperature sensor and inverter/control fuses.
🏭
Kohler Marine
1 ✓ 1 verifiziert⚙️
Kohler 40EFOZDJ Marine Generator
✓ verifiziert
PREMIUM
Per ship electrical load analysis
· 40.0 kW
· Diesel
engine_model: None
cylinders: None
configuration: None
displacement_l: None
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel']
application: marine generator set
Common Failures:
- • Seawater pump impeller failure
- • Heat exchanger fouling
- • Starter and solenoid faults after humid engine-room exposure
Service: Typical routine maintenance includes oil/filter service, fuel filter replacement, impeller inspection and load testing according to Kohler manual.
Spares: Keep impeller kit, filter kit, belts, zinc anodes if fitted, starter solenoid and control fuses.
🏭
Nanni
1 ✓ 1 verifiziert⚙️
Nanni QLS 32T Marine Generator
✓ verifiziert
Inspector
Per ship electrical load analysis
· 24.0 kW
· Diesel
engine_model: None
cylinders: None
configuration: None
displacement_l: None
rpm: 1500
frequency_hz: 50
fuel_types: ['Diesel']
application: marine generator set
Common Failures:
- • Raw-water pump impeller failure
- • Heat exchanger fouling
- • Exhaust mixing elbow corrosion
Service: Routine service includes oil/filter change, fuel filters, impeller inspection and coolant checks according to Nanni schedule.
Spares: Keep impeller kit, filters, belts, zincs if fitted, thermostat and glow plugs.
🏭
Wärtsilä
3⚙️
Wärtsilä Shaft Generator - economical electrical power generation
source: Wärtsilä
model_number: Wartsila Shaft Generator
⚙️
Generator Protection Module, GPM 500, Diesel Protection Module, DPM 500
source: dnv-approval-finder
model_number: TAA00000F1
⚙️
Moss Inert Gas Generator System
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000013H
🏭
ABB Marine
2⚙️
ABB AMG Marine Synchronous Generator
source: verified_megafleet_2026-06
model_number: AMG (Synchronous Generator)
type_specs: {'Leistungsbereich LV': '14 kVA - 5000 kVA; Spannungen 380-690 V (50/60 Hz)', 'Leistungsbereich HV': 'bis 63 MVA; Spannungen bis 15 kV (50/60 Hz)', 'Rahmengroessen': 'LV: 180-630; HV: 500-2500; Pedestal: 1250-2500', 'Isolationssystem': 'VPI (Vakuum-Druck-Traenkung) Klasse H/F fuer Stator und Rotor', 'Wicklung': 'Polyester-Imid-Harz mit hoher Dielektrizitaets- und Feuchtebestaendigkeit', 'Kuehlung': 'Doppel-Axialventilatoren, Wasser-/Luftkuehlung moeglich; Umgebungsbereich -20°C bis +45°C, Hoehe bis 1000m', 'Lagerung': 'Sealed-for-life (Frame <400) oder nachfettbar (Frame 450); Pedallagerkonstruktion fuer groessere Frames', 'AVR-System': 'UNITROL 1000 Serie oder GEN06/GEN08 AVR; 100 kVA - 80 MVA; U/Hz, UEL, OEL Limiter', 'Schutzstandard': 'IEC 60034-18-32 fuer Isolationsalterung; IEEE Std 117-1974; Klassifizierungsgesellschaften zertifiziert'}
product_lines: ['AMG Synchronous Generator Series (14 kVA - 2600 kVA LV; up to 63 MVA HV)', 'LV Standard Marine Generators (400-5000 kVA, Frame 400-630)', 'LV Modular Marine Generators (560-2400 kVA, Frame 400-450)', 'HV Pedestal Bearing Generators (up to 60 MVA, Frame 1250-2500)', 'Shaft Generators (Permanent Magnet, up to 4 MW)']
needs_verification: False
datasheet_url: https://library.e.abb.com/public/8c68bd05fb4e40be820b6d6c5c6ed385/Marine_generators_brochure_9AKK106085_rev.C.06-2021_lowres.pdf
Common Failures:
- • _hinweis
- • items
⚙️
ABB Marine Shaft Generator
source: verified_megafleet_2026-06
model_number: Marine Shaft Generator
type_specs: {'Leistungsbereich LV': '14 kVA - 5000 kVA; Spannungen 380-690 V (50/60 Hz)', 'Leistungsbereich HV': 'bis 63 MVA; Spannungen bis 15 kV (50/60 Hz)', 'Rahmengroessen': 'LV: 180-630; HV: 500-2500; Pedestal: 1250-2500', 'Isolationssystem': 'VPI (Vakuum-Druck-Traenkung) Klasse H/F fuer Stator und Rotor', 'Wicklung': 'Polyester-Imid-Harz mit hoher Dielektrizitaets- und Feuchtebestaendigkeit', 'Kuehlung': 'Doppel-Axialventilatoren, Wasser-/Luftkuehlung moeglich; Umgebungsbereich -20°C bis +45°C, Hoehe bis 1000m', 'Lagerung': 'Sealed-for-life (Frame <400) oder nachfettbar (Frame 450); Pedallagerkonstruktion fuer groessere Frames', 'AVR-System': 'UNITROL 1000 Serie oder GEN06/GEN08 AVR; 100 kVA - 80 MVA; U/Hz, UEL, OEL Limiter', 'Schutzstandard': 'IEC 60034-18-32 fuer Isolationsalterung; IEEE Std 117-1974; Klassifizierungsgesellschaften zertifiziert'}
product_lines: ['AMG Synchronous Generator Series (14 kVA - 2600 kVA LV; up to 63 MVA HV)', 'LV Standard Marine Generators (400-5000 kVA, Frame 400-630)', 'LV Modular Marine Generators (560-2400 kVA, Frame 400-450)', 'HV Pedestal Bearing Generators (up to 60 MVA, Frame 1250-2500)', 'Shaft Generators (Permanent Magnet, up to 4 MW)']
needs_verification: False
datasheet_url: https://library.e.abb.com/public/8c68bd05fb4e40be820b6d6c5c6ed385/Marine_generators_brochure_9AKK106085_rev.C.06-2021_lowres.pdf
Common Failures:
- • _hinweis
- • items
🏭
ABB Oy, Distribution Solutions
2⚙️
Feeder Protection REF615, Motor Protection REM615, Voltage Protection REU615, Line-differential Protection RED615 and Transformer Protection RET615, Generator and interconnection protection REG615 & Capacitator bank protection and control REV615
source: dnv-approval-finder
model_number: TAE000014Y
⚙️
Feeder Protection REF630, Motor Protection REM630, Generator Protection REG630 and Transformer Protection RET630
source: dnv-approval-finder
model_number: TAE000039T
🏭
DEIF
2⚙️
Uni-line Generator controls
source: dnv-approval-finder
model_number: TAA00000Z2
⚙️
PPU-3, GPU-3 - Generator Controllers and Protection, PPM-3 - Power Management System
source: dnv-approval-finder
model_number: TAA00000KD
🏭
Solar Turbines
2⚙️
CENTAUR 40, 50 CS/MD & GENERATOR SET, TAURUS 60, 65, 70 CS/MD & GENERATOR SET, MARS 90, 100 CS/MD & GENERATOR SET, TITAN 130, 250 CS/MD & GENERATOR SET
source: dnv-approval-finder
model_number: TAS000017R
⚙️
Centaur 40/50, Taurus 60/70, Mars 90/100, Titan 130, Titan 250 Generator Packages
source: dnv-approval-finder
model_number: TAM0000025
🏭
Air Products
1⚙️
Marine Nitrogen Generator, Cabinet Model NC1, NC1-1204P---NC1-1816P, NC1-1408S---NC1-2024S, NC1.3-0803--NC.1.3-5896, NC1.3-1814S--2024S, Cabinet Model NC0, NC.0.3-0803, MDC1.0-0603---MDC1.0-1008, NC2.1-1750, NC2.1-3000, NC2.1-6000, MSC1.0-0820---MSC1.0-3072, MSC2.0-0820---MSC2.0-3072
source: dnv-approval-finder
model_number: TAP00001E8
🏭
Cummins Generator Technologies
1⚙️
Type UCM 224, 274, HCM 534/S5L 1M, 634, S4L 1M,
PM 734/S7L1M and S6L1M 3 phases, 4 poles, single or 2 bearings
brushless A.C. generator.
source: dnv-approval-finder
model_number: TAE000018X
🏭
GE Gas Turbines
1⚙️
GE Mk VIe and GE Mk VIeS Turbine Controllers for Electric Motor / Compressor Set and for Turboexpander / Generator Set
source: dnv-approval-finder
model_number: TAA000001E
🏭
HWA YOUNG
1⚙️
Digital Panel for Marine Generator Engines (DGP-2000)
source: dnv-approval-finder
model_number: TAA00001WS
🏭
JiangSu Enda General Equipment Group
1⚙️
ED212 Self Starting Panel for Generator
source: dnv-approval-finder
model_number: TAA00000EV
🏭
Kashiwa Co., Ltd., Tsukuba Works
1⚙️
Inert Gas Generator, Model No.; KGG-500
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000019C
🏭
Kongsberg
1⚙️
Kongsberg Hybrid shaft generator
source: Kongsberg Maritime
model_number: Hybrid Shaft Generator
🏭
Kumoh Mach. & Elec
1⚙️
Generator Engine Automatic Control System (GECS)
source: dnv-approval-finder
model_number: TAA00003RG
🏭
Mecc Alte
1⚙️
ECO38, -40, -43, -46 and ECP32, -34, 3 phases, 4 poles, single or double bearings, brushless A.C. generator.
source: dnv-approval-finder
model_number: TAE000017N
🏭
Micoda Process Systems International
1⚙️
Frame for Generator
source: dnv-approval-finder
model_number: TAS0000483
🏭
PAC Eastcoast Engineering & Services
1⚙️
Frame for Generator
source: dnv-approval-finder
model_number: TAS0000534