Alfa Laval
Marine Calorifier
Steam/electric hot water calorifier for domestic hot water supply on board.
12.0 kW
Power
200-2000 L, 60-80°C
Capacity
Freshwater
Medium
🔧 Komponenten & Aufbau
Component data being added…
📊 Technische Daten
medium
Freshwater
power kw
12
type
Marine Calorifier
⚠️ Typische Ausfälle
- ● Heating coil scaling
- ● Electric element burnout
- ● Thermostat failure
- ● Anode depletion causing tank corrosion
🔍 Service & Wartung
Replace sacrificial anode annually. Descale heating coil every 2 years. Thermostat calibration annually. Legionella prevention: maintain >60°C.
📦 Verschleißteile
Spare parts data being added…
Ersatzteile über Alfa Laval oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.