OS
← Component Tree

Crankcase Oil Mist Detector

critical
Parent: Lubrication System

Components for this Group (2)

Schaller Visatron VN215+ OMD
MAN Energy Solutions ME/ME-C · Supplier: Schaller Automation
2w
Common Failures:
  • • Sensor fouling giving false alarms
  • • Sample pipe blockage
  • • Reference cell degradation
  • • Relay output failure
Service: SOLAS mandatory. Test weekly. Clean sensor optics every 4,000 hrs. Replace reference cell every 2 years.
Weight: 8.0 kg
GEA Westfalia OMD / Schaller VN215+
WIN-GD X-DF · Supplier: GEA / Schaller Automation
2w
Common Failures:
  • • Sensor window fouling
  • • Sample extraction fan failure
  • • False alarm from crankcase ventilation change in gas mode
Service: Same as diesel — SOLAS mandatory regardless of fuel. Test weekly.
Weight: 8.0 kg